Horizontal TEFC Motor Silencers
Our TEFC Motor Silencers are used on the inlet end of all horizontal TEFC
motors to quiet the sound radiating from the internal cooling fan. The fans
on TEFC motors are typically the sound source for offending levels. These VA
units are especially suited for applications where space behind machinery is
limited or is important to preserve access. Please contact the factory for
specific recommendations.
They can be adapted to any and all sizes of TEFC motors from 10HP through
4000HP motors. They typically provide between 35-50 dba of attenuation and
do not restrict the required airflow of the motors on which they are
installed. All of our VA Series silencers incorporate our Oxel spirals.
Please refer to the "TEFC Size/Selection" chart for proper sizing based on
airflow and HP.
*This
information is necessary if
holes are
to be pre-punched. If
these
specifications are not furnished, mounting flanges
must be
drilled on the job by
installer.
Silencer
construction is Aluminum.
Adapter
fitting is steel.
Both have
powder coat finish.
Each unit
is complete with two
Oxeld
square attenuating spirals,
mounting
gasket, adapter fitting,
and inlet
screen.
We will
identify silencers by
area, fan,
or motor number
only if
its requested.
MODEL NUMBER
Dim
VA 77-2S
VA
88-2S
VA
99-2S
VA
1010-2S
VA
1212-2S
VA
1414-2S
VA
1420-2S
VA
1624-2S
VA
1826-2S
A
20
22
24
26
30
34
34
38
42
B
11
12
13
14
16
18
18
20
22
C
36
38
40
42
44
52
58
64
72
INLET SIZE
(USER
SPECIFIED)
D
O.D. OF
FLANGE
(USER
SPECIFIED)
E
F
12½
13½
14½
15½
17½
19½
19½
24½
28
*SIZE OF
BOLT CIRCLE
NUMBER &
SIZE OF
MOUNTING
BOLTS
*LOCATION
OF 1ST
BOLT (0
DEG AT 3 OCLOCK, ETC.)
ATTENUATION AND AIR FLOW
Model
number
INSERTION
LOSS AT 3FT.
AIR FLOW
CFM
APPROX.
WT. IN LBS.
B.B.
dBA
125
dB
250
dB
500
dB
1000
dB
2000
dB
4000
dB
@
0.50
@
0.75
SILENCER
ADAPTER
VA 77-2S
45
31
30
28
37
48
63
1420
1650
34
12
VA 88-2S
44
35
33
45
42
46
63
2600
2900
42
14
VA 99-2S
43
29
29
45
42
47
63
2900
3350
49
16
VA 1010-2S
46
29
32
39
45
51
63
4900
5600
54
18
VA 1212-2S
46
29
38
37
43
53
63
6500
7400
68
20
VA 1414-2S
46
28
35
34
36
49
63
7900
8200
85
24
VA 1420-2S
47
28
32
41
39
47
63
9400
10300
91
24
VA 1624-2S
52
31
34
38
47
49
62
12000
13800
126
50
VA 1826-2S
44
28
29
34
36
46
62
15000
16100
176
80
Above
reading were taken during in-plant tests of Silencers. Air flow and
pressure drop tests follow the joint
Standard ASHRAE
51-75 and AMCA 210-74.
Attenuation tests made in large reverberant room, reading high level
noise at selected frequencies, open speaker, and attenuator in
place, using
GENRAD 1565-A
And
1933
meters, calibrated with 1562-A
calibrator before test. Broad band noise generated by GENRADtype 1390-A
noise source.
TYPE 1 ADAPTER TYPE 2
ADAPTER TYPE 3 ADAPTER
TAPER
CONNECTS SILENCER TO
LARGER
SIZE INLET ON MOTOR
ADAPTER IS
STRAIGHT NO TAPER
ADAPS
LAGER SIZE SILENCER
TO SMALLER
AIR INLET ON MOTOR
NOTE:
Special adapters can be furnished for your requirements if you will supply a
sketch. Adapters have internal acoustical treatment. Adapter types 1,2, and
3 will be punched to match the mounting flange of your equipment if you
specify numbers and size of bolt holes and diameter of bolt circle. In
ordering vertical silencers, VA series, specify location of first bolt, i.e.
0 degrees (3 oclock) etc.